Can frames be filled with grout before installing
”
RELATED FAQS
Question
Answer
Can a filler or cover plate be used to blank out a EPT prep on a fire rated frame?
Resolution:
Yes, a filler plate can be used to cover an EPT prep as long as it is made from the same material as the frame. This information can also be found in NFPA 80 under Chapter 5 for Field Modifications.:
Why is a bituminous back-coating used?
Resolution:
Some architectural specifications require steel frames to be back-coated with a bituminous coating for corrosion protection or sound control. It is commonly specified to be used in condit...:
Why are frames grouted?
Resolution:
Grouting frames is: A process done in the field during hollow metal frame installation The internal cavity of the frame is fill with masonry or mortar It is intended to mainly provide ...:
What is the replacement for the Locknetics 9100 series electric strike?
Resolution:
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes. The 6211 is used if the frame is being replaced. The 6210 is for ...:
How do you install a 4110 with flush transom frame?
Resolution:
The 4110 series closer is installed on a flush transom frame using the -419 flush panel adapter.:
What options are available to add frame reinforcement for surface closer?
Resolution:
Steelcraft offers two optional types of reinforcements for open section header to be installed in distributor shop or in the field: Full profile sleeve; is a 14 gauge, 16" long part to fit the p...:
How many compression anchors are provide per jamb on DW-Series frames?
Resolution:
For compression anchor details refer to the “ANCHORING SYSTEMS” section in the Steelcraft Tech Data Manual.Anchor Quantities: • 1 compression anchor per jamb through 9"depth • ...:
Can "toed in" or "toed out" jambs be adjusted?
Resolution:
This condition (toed in or toed out jambs) is usually not found until the door is installed.Frames which have toed in or toed out jambs have been installed out of tolerance.It is the responsibility...: