can fire rated devices be dogged
”
RELATED FAQS
Question
Answer
Can dogging be added to a Von Duprin fire rated exit device?
Resolution:
No, dogging cannot be added to a fire-rated mechanical exit device. Fire rated devices can be only electronically dogged and drop during fire activation.:
What Steelcraft doors can be prepped for a Von Duprin InPact device?
Resolution:
Steelcraft L-Series and T-Series doors are available (as an option) factory prepared for the Von Duprin InPact exit device. :
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
What is the part number for the former F588 from Monarch?
Resolution:
The top latch for a Fire rated surface vertical rod device is part #650375-00 which replaced the old part #F588.:
Where do I install my Auxiliary Fire Latch (AFL) in a Less Bottom Rod, Fire Rated (LBR-F) exit device?
Resolution:
Installation should be 6" from bottom of the door. See attached templates as reference. T-5494 for HM Doors W-5494 for Wood Doors:
Can Steelcraft doors be prepped for the 98/9949 Concealed Vertical Cable Exit Device?
Resolution:
Yes, as an option, Steelcraft doors are available with factory prepared for the 98/9949 Concealed Vertical Cable Exit Device.L, B, CE, T and CE-Series doors are available factory preparedDoor prepa...: