What is the part number for a blade stop shim for a 6111 or 6113 electric strike?
Resolution:
010055-xx is the part number for Blade Stop Shim kit for 6111 or 6113 electric strike and it must be ordered separately. xx is for the finish callout.:
BLADE STOP SPACER
Resolution:
Shoe Spacer, Parallel Arm Closers, Aluminum Frame, Aluminum Store Front Frame:
BLADE STOP
Resolution:
Aluminum Frame, Aluminum Store Front Frame, Aluminum Door and Frame:
What other locks can the blue lever removal tool 24002693 be used with?
Resolution:
On August 15, 2012 Schlage began shipping a new, more ergonomic, lever removal tool to coincide with Phase 1 of the ND-Series improvement project. This tool can be used for Schlage ND-Series ...:
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
Can I use a Glynn Johnson 410 with a 4040 regular (pull side) mount?
Resolution:
ST-1630 is required when mounting a 4041 or 4040XP door closer regular (pull/hinge) side with a concealed GJ100 or GJ410 series over head stop.This ST also REQUIRES the use of a 4040-18TJ drop plat...:
What special template (ST) is used with a 2030 closer and GJ over head stop?
Resolution:
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...:
Can a Glynn Johnson 90 stop be used with a top jamb mounted 4040?
Resolution:
A 4040-18G drop plate will be needed to drop the closer and arm down far enough not to conflict with the GJ 90 series overhead stop.:
What is a 62A shoe used for?
Resolution:
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.:
Can I mount an LCN Cush closer with an GJ overhead stop?
Resolution:
It would be unnecessary to use the CNS/Cush arm and the Glynn Johnson overhead devices in the same application, both mechanisms stop the door.:
Is the blue ND lever tool shipped with each lock?
Resolution:
The blue lever tool remover, 24002693, is not shipped in every box. The existing wire spring lever removal tool will be included in every box. :
How do you mount a 55 rim with the 379 where the studs do not line up with the mounting screws?
Resolution:
Position the 379L trim and attach with countersunk screw into the bottom stud of the trim. Position the 55 Rim device and attach with the device mounting screw through the he...:
Why do the mounting studs on the 379L not line up with the back of the 55 rim?
Resolution:
The existing 373L control was modified and re-named as 379L to allow us to use the 55 rim device on an ADA door opening. The 379L control is our 373L with different hex ...:
How do you remove an AL lock from a door?
Resolution:
AL-Series and discontinued D Lever-Series locks use castle nuts to hold the chassis to the spring cages and to keep the chassis positioned in the door. This causes confusion at times when the lock ...: