automatic flush bolt electric

RELATED FAQS

Question
Answer
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted.  During a fire alarm, the contact will open, dropping...
LR is the regular/ standard latch and PL is Pullman/ES (Electric Strike) latch for the Von Duprin 8827 exit device.
 ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike
On a single door take the mounting dimensions from centerline of pivots.  On a pair of doors, depending on the door width and pivots being used, the operators can butt up against each other or ov...
Astragals are required on: 3 hour fire rated pairs: Double doors - swinging in the same direction Double Egress - swinging in opposite directions Fire rated Dutch Doors Fire rated 1 3/4" t...
Dezigner Trim – This unique and patented glass trim has been designed to closely simulate trims installed in wood doors and is factory: Supplied recessed into the door face, to provide a neat f...
Flush Mounted Steel Trim for Insulated glass – Designed for 1” thick insulated glass. Recessed into the surface of the door face Accommodates 1" (25 mm) thick glass. When installed, fastener...
Overlapping Steel Trim (also refer to as conventional steel trim) – This trim is the typical glass trim supplied by most hollow metal manufacturers. Surface mounted on the door face. Accommo...
Flush Mounted Steel Trim – This trim is similar to Overlapping Steel Trim but is factory supplied recessed into the door face and is available for 1/4” glass. Glazing stops are screw attached, fast...
 Basic glass trim details:
See the link to a video instruction, Concealed Vertical Rod Exit Device Adjustment.Manual steps:Open door and release top latch bolt by inserting a screw driver in the hole at the top of the d...
Panic Hardware and Fire Exit Hardware are two different types of exit devices, and the proper selection is determined by code requirements. Panic Hardware is an exit device which is tested for u...
The most obvious difference (in the device) is the lack of mechanical dogging on a Fire Rated Device.  There are some internal parts that may be different and the method it is secured to the d...