are impact resistance testing

RELATED FAQS

Question
Answer
Kits are available per the following criteria.    Product Bulletin Required Series 94 or 95 Fire or Panic 3FT/4FT or 2 ft 6 in / 2 ft 10 in Finish  Optional LX...
Backset dimensions will vary depending on the device, application and the opening configuration. If you have questions on specific device backsets, please e-mail your request (including a descripti...
The best way to test the Von Duprin EL solenoid is with an ohm meter. You must test both coils to make sure the solenoid is good. The coil has three wires; green, yellow, and orange. The green...
Only applicable for solenoid driven Chexit devices shipped from the factory prior to 8-24-2015; Chexit solenoid coil resistance between the green and orange wires is 110-140 ohm and betw...
The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...
To check an ME or SE solenoid Unplug the solenoid from the circuit board. Measure resistance across the 2 pin of the solenoid connector. The solenoid resistance should read: 24 volt solenoi...
Schlage does not test their locks for ballistics or bullet resistance.
The L-Series doors are designed for virtually all construction requirements in commercial building applications. They have also been tested and approved for uniform wind load per ASTM E330.  ...