Arch top doors

RELATED FAQS

Question
Answer
CE Series door in a variety of embossed panel designs and gages. The CE series embossed panel doors also offer a wide range of specifiable options including sizes, glass light designs and hardw...
Minimum dimensions to cutouts for glass lights: Vertical edge of door to edge of cutout = 5 29/32" Top of door to top of cutout = 6" Bottom of door to bottom of cutout = 10" Reinforcing chann...
 8827 vertical rod device is available for 7 or 8 feet tall door standard. 12", 24", 36" and 48" extension rod kits are available for taller doors (8 feet max on fire rated openings). We do no...
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate.  If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.
High Definition (High Def) door panel designs have deeper shadow lines than conventional CE-Series designs. CE-Series doors are available with optional High Definition (HD2 and HD2A) door panel de...
The 2030 closer requires a minimum 1-3/8" top rail on the door for the standard track.  For a top rail less than 1-3/8" and as narrow as 1", you could use the l...
Maximum Dutch Door sizes are: Non Labeled = 4'0" wide X 8'0" High Labeled = 4'0" wide X 7'2" High Special sized Dutch Doors are available: Special size top and/or bottom leaves are availabl...
4640 Flush Ceiling mounting requires a minimum 1-3/4" Header, and a minimum 3-3/4" Top Rail on the door.
From head to centerline of each hinge (4 1/2" or 5") is 9 3/4", 39 3/64", 68 11/32" & 97 41/64".
The hinge spacing on a 9'0" frame opening height is 29 19/64".
From Head to top of each 4 1/2" hinge is 7 1/2", 36 51/64", 66 3/32" & 95 25/64". From Head to top of each 5" hinge is 7 1/4", 36 35/64", 65 27/32" & 95 9/64".