The Schlage L9000-Series with anti-ligature trim cannot be ordered less cylinder (L cylinder suffix), but can be ordered less core (BD or J cylinder suffix). The cylinder rose dimensions change bas...
The door handing determines the finish of the latch and strike. Left reverse and right reverse doors default to outside trim Left and right hand doors default to inside trim If lever an...
With split key construction keying there are two ways the construction insert is retained in the cylinder so that it won't fall out the back end of the plug, see Figure 1.  The&nb...
Schlage offers a High, Medium, and Low risk HSLR ligature Resistant trim offering for the L9000 and ND locks, Data Sheet.Schlage offers a Low to Medium Risk SL1/SK1 ligature resistant trim for...
High Risk Areas*Patient bedroomIn-suite bathroomIn-suite closetTime-out roomPatient difficult to manage; or risk of solitary and/or unsupervised areas.Medium risk areas*Living roomDining roomGroup ...
Torx screws are not standard on the SL1/SK1 trim but are available as an option. Specify the L283-121 Torx screw pack.  This pack includes torx screws for the armor and strike. 
The Schlage SL1 ligature resistant lever is designed to break-away between 100 and 200 inch-pounds.  The lever will rotate at this point but not allow access.