alk makes keep flashing
”
RELATED FAQS
Question
Answer
Can the Von Duprin exit alarm ALK and electric latch retraction QEL or EL device be in the same device?
Resolution:
No, Von Duprin exit alarm ALK and electric latch retraction QEL or EL are installed in the same location and can't be ordered together with the same device.:
Is the external inhibit option standard on the " new " ALK from Von Duprin?
Resolution:
The current Von Duprin ALK comes standard with the External Inhibit feature.:
How do I wire an EL device to normally hold open the latch and release it during a fire alarm?
Resolution:
Use a normally closed fire alarm as the input to the power supply option board (PS873-2 or PS914-2RS), this will hold the latch retracted. During a fire alarm, the contact will open, dropping...:
Does the current Von Duprin ALK have an EI?
Resolution:
Current exit alarm ALK released in November 2010 does ship standard with an EI (external inhibit) option. ALK shipped prior to this would only have EI if ordered as a Special option.:
Chexit goes into alarm with fast flashing LED and not locking after rearm time.
Resolution:
Chexit devices shipped prior to 8-24-2015 with solenoid driven: Chexit device has a RX switch with a connector that needs to be connected to the Chexit module otherwise the alarm will sound af...:
Alk not power up - using 9V battery
Resolution:
There are three main failures with an ALK. Problems are usually caused by a bad power source(battery), bad RX/LX Switch or a bad circuit board. Try installing a new battery and wai...:
Why would the ALK chirp?
Resolution:
A low battery could cause the exit alarm ALK to chirp. Replace the battery and if it is still chirping, then replace the circuit board part number 101030-00.:
Will an ALK sound when the exterior trim is used to enter from the pull side?
Resolution:
The ALK exit alarm will sound when the exterior trim is used to enter from pull side without using access control when an LX latch bolt monitor switch is used instead of RX push bar monitor switch.: