Question
Answer
What is AR1, AR3, or AR6 on a Von Duprin exit alarm ALK?
Resolution:
AR1 is Auto-Reset 1.5 minute, AR3 is 3 minute, or AR6 is 6 minute option processed through engineering specials on a Von Duprin exit alarm ALK.:
Can the Von Duprin Chexit device be changed to ALK exit alarm?
Resolution:
The Chexit device has a different base plate and center case than the ALK. The Chexit device would need to be replaced with an ALK device.:
What is the part number for the EAK PCB only for Monarch Falcon devices?
Resolution:
This circuit board will NOT work on the updated 24/25 Alarm Kits that released June 11th, 2012.:
Is a switch required to operate the Von Duprin ALK unit?
Resolution:
Yes. The exit alarm ALK is shipped standard with a RX, request to exit switch, but can work with the optional LX, latch bolt monitor switch. If there is no switch in the device it will never alarm.:
Will an ALK sound when the exterior trim is used to enter from the pull side?
Resolution:
The ALK exit alarm will sound when the exterior trim is used to enter from pull side without using access control when an LX latch bolt monitor switch is used instead of RX push bar monitor switch.:
Why should you use the LX switch with an ALK being used in Von Duprin surface vertical rod devices?
Resolution:
You should use the LX switch with the Von Duprin surface vertical rod exit device because the rods are exposed and are vulnerable to attack. IE, the top rod can be grasped and forced down to retrac...:
How do you specify an exit alarm ALK with a hard wire to the power supply?
Resolution:
All new 22, 33/35A and 98/99 series exit devices with exit alarm ALK option can be hard wired to the PS902 power supply as a standard feature.:
Can automatic door bottoms be installed in standard Steelcraft doors?
Resolution:
Special (custom) option: a special/optional end channel that will support the following manufactures: National Guard (422/423/522) Pemko (443) Zero International (360/364).:
What power supply replaces the Von Duprin 9VDC PS9 power supply?
Resolution:
The PS9 power supply was discontinued. The new exit alarm ALK can either use a 9VDC battery or 24VDC regulated power supply. There is no direct replacement for Von Duprin PS9 power supply. Cur...: