Question
Answer
How do you slow down the closing speed of the 4600 series operator?
Resolution:
The hydraulic closer underneath the control box has 3 regulating valves (like any 4040 series hydraulic closer). Main Speed - adjust closing speed from 90° open down to 10°. Latch Speed - adju...:
Is there adjustment limits on the regulation valves of LCN manual closers?
Resolution:
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valv...:
What is the delay time adjustment on a Delayed Action closers?
Resolution:
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...:
What would cause an ME Series closer (2310ME/4310ME/4410ME) to pop back into hold open as it is closing?
Resolution:
This condition can be caused by the "closing speed adjustment" being regulated for a fast closing speed. Try adjusting the closing speed to slow down the closing of the door. If that does not corre...:
How do you adjust a door closer?
Resolution:
How to: What are the steps to adjust a door closer? Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment. All cl...:
How to adjust First, Delay, and Retry in a PIM400 & AD400?
Resolution:
To change FIRST/DELAY/RETRY connect and couple the SUS/HHD to the AD400 and find under the EDIT tab the FIRST/DELAY/RETRY settings. See notes Or connect the SUS/HHD t...:
FAST POWER ADJUST
Resolution:
power adjustment, spring adjustment: