Question
Answer
Can a Von Duprin delay egress controller DE5101 run a pair of doors?
Resolution:
One Delayed Egress Controller (DE5101) can run two mag locks on a pair of doors, provided the doors are not controlled independently:
Will a Von Duprin Chexit device automatically rearm itself after a fire alarm clears?
Resolution:
The Von Duprin Chexit device will not automatically rearm itself after a fire alarm clears. After a Fire Alarm has triggered the Von Duprin Chexit device, the device must be manually reset&nb...:
What does BOCA mean for the Von Duprin Chexit option device?
Resolution:
The Von Duprin Chexit-BOCA has special software. Following is the function of this software: When Chexit device push bar is pushed and goes into alarm it will release in 15/30 sec...:
What took the place of the Von Duprin 873-DE option board?
Resolution:
The delay egress is controlled in the exit device (Von Duprin Chexit), the magnetic lock, or other locking device.:
Does Falcon offer a Delayed Egress exit device?
Resolution:
There is not a fully self-contained delayed egress like a Von Duprin Chex-It device but the Falcon RX-24 or RX-25 Series can perform a delayed egress by using the DE5300 controller, power supp...:
What is delayed egress hardware?
Resolution:
Delayed egress hardware prevents a door from being opened from the egress side, usually for a period of 15 seconds. This type of device is often used to prevent theft, while maintaining life safe...:
Does the M490DE come with a delayed egress warning sign?
Resolution:
A delayed egress sign is provided with the M490DE and the M490DEP. The sign's part number is P774358:
DELAYED EGRESS
Resolution:
CX, DE5101, RCM, DE (390DEL, DE5101, CX, RCM, 390+DEL, 101+, 101+ Series):