Question
Answer
What parts are necessary to add the bottom rod/latch/strike to a 98/9927-LBR/LBR-F (less bottom rod) device?
Resolution:
Following parts are required to add the bottom rod and latch to the 98/9927-LBR/LBR-F device. Bottom Rod: 050515 for 9827 and 050514 for 9927 (specify finish) Bottom Latc...:
What is the minimum clear opening width required by ADA on a single door?
Resolution:
The minimum clear opening width for ADA is 32" measured from face of door opened to 90 degrees to face of stop on strike jamb. There must be no hardware mounted to the door projectin...:
What would keep the vertical rod exit devices top latch from being held retracted in the open position?
Resolution:
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...:
Can the electric strike be used with a vertical rod device on a fire-rated door?
Resolution:
Not for use in fire rated openings.:
Is the 8827 available LBR?
Resolution:
Von Duprin offers a PL8827 LBR device with a pullman style top latch and Less Bottom Rod for use with electric strikes, but is not UL labeled nor ANSI/BHMA certified.:
How long are the rod lengths for the 25-V?
Resolution:
The top and bottom rod itself is 35" long standard.:
Is the 2227 panic exit device available LBR?
Resolution:
The Von Duprin 2227 or 2227-F exit device is available less bottom rod. Specify 2227-LBR or 2227F-LBR for fire.:
Will the 25-C series rods and latches work on the old 18-C?
Resolution:
The internal rods and latches for the 25-C carried over from the older 18-C device so they can be used interchangeably.:
Why would an EL1690 retract the rods but not hold them?.
Resolution:
One of the following items may cause the EL1690 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...: