All Keypad ONLY credentials with firmware versions between 2.9.2 and 2.11.0 should be updated to the latest firmware available at www.schlage,com/support.
A firmware issue with Keypad ONLY credential firmware, versions 2.9.2 through 2.11.0 and manufactured between 9-9-2010 and 1-5-2011 will exhibit poor battery life.
The Keypad ONLY credential Reader (KP) can prevent the reader from entering its low power sleep mode - with firmware versions 2.9.2 through 2.11.0
A Technical Note has been generated to document one method of measuring battery current. See the attachment HERE.
Causes for AA battery drain in AD-Series LOCKS Possible Cause Fix/Corrective Action 1)      One the four (or eight) AA was inserted reversed and the rese...
Information on low battery threshold and nuisance delay is noted below: New firmware now has improved levels. - These are approximate values/levels which change with measurement meters and measure...
AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 4 Battery Holder New batteries = 6.2 VDC Low battery threshold is 4.7 VDC for SM & MT - and 3.7 VDC for MAG and PROX (USB stops working at 4...
    AD400/AD200/AD250 After ADFwPkg 2.17.0 - June 2011 8 Battery Holder New batteries = 12.4 VDC Low battery threshold is 7.2 VDC Critical battery threshold is 6.9 VDC Coin cell = new/...
CO2004 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
CO2504 Battery Holder (ONLY) New batteries = 6.2 VDC Low battery threshold is 4.2 VDC Critical battery threshold is 3.9 VDC Coin cell = new/full is 3.0 VDC, low is 2.8 VDC
  CO200 & CO250 Disable coin cell Nuisance delay and blink, With CO.A.7 and SUS 4.10.2 or newer for CO200 and CO250, you can use the SUS/HHD, under Lock Properties, Edit, to de-select, DISABLE, t...