Question
Answer
Gauss reading for GF3000
Resolution:
The magnetic gauss reading (magnetic flux for the armature) is 20 gauss at 1.5 inches from armature all around it and no gauss reading after 2.5 inches.:
GF3000 with reversed polarity
Resolution:
GF3000 with reversed polarity will not have a relock delay, which means it will not have a thirty second delay, it will still lock but instantly.This may potentially damage the module and not ...:
What is the nearest functional replacement for the Max hold SL4110 Mag lock
Resolution:
No direct replacement, but GF3000 would be the closest.:
GF3000 coil does not float
Resolution:
Current production GF3000 have a fixed , solid coil. Previous models excluding the BRD hadĀ spring load floating coils. This allowed the coil to drop and meet the armature, EngineeringĀ is reviewing ...:
GF3000 Power Supply
Resolution:
At 12 vdc 2 GF3000's will need 1.8 amps , lvery close to the PS902 supplies limit. If running at 24 vdc technically 4 units would draw 1.8 amps . A limit of 3 would be bet...: