320+ 350+ 390+ Unit will not bond
Resolution:
check the following:Properly polarized power inputCorrect voltage 12 or 24 VDC Negative - must be on terminal 1 and the Positive + wire must at terminal 2.Power supply has adequate current to ...:
Dynamic Holding Force for Maglocks
Resolution:
The dynamic holding force of a magnetic lock refers to the amount sudden impact force necessary to defeat the magnetic bond of the mag head with the armature. Normal or Static holding f...:
ANSI Numbers with Maglocks
Resolution:
ANSI number Product cross reference can be found in the back of the price book. For example, ANSI number E08561 is specifically for the GF3000, GF3000TJ:
what is the wiring to by pass the electronics board for to 390+ magnetic lock
Resolution:
12VDC - red/black = positive blue/white = negative 24VDC - red = positivewhite = negative Connect blue/black:
What voltage is too low on a mag lock what voltage is too high on a mag lock What is the range of voltage for the M4xx locks What is the range of voltage for the mag locks
Resolution:
Anything outside of + or - 10% is out of range: