Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
Schlage Electronics
Question
Answer
320+ 350+ 390+ Unit will not bond
Resolution:
check the following:Properly polarized power inputCorrect voltage 12 or 24 VDC Negative - must be on terminal 1 and the Positive + wire must at terminal 2.Power supply has adequate current to ...:
Dynamic Holding Force for Maglocks
Resolution:
The dynamic holding force of a magnetic lock refers to the amount sudden impact force necessary to defeat the magnetic bond of the mag head with the armature. Normal or Static holding f...:
ANSI Numbers with Maglocks
Resolution:
ANSI number Product cross reference can be found in the back of the price book. For example, ANSI number E08561 is specifically for the GF3000, GF3000TJ:
what is the wiring to by pass the electronics board for to 390+ magnetic lock
Resolution:
12VDC - red/black = positive blue/white = negative 24VDC - red = positivewhite = negative Connect blue/black:
Can the 268-10 or 320 Maglocks without circuit boards be wired for 12 or 24 VDC
Resolution:
(12VDC: Red ties to positive(+), White wire ties to negative(-), Black & Blue wires tied together) (24VDC: Red and Black wires tied together connect to positive(+), Blue and White wires t...: