Falcon
Question
Answer
What is the part number for the former F588 from Monarch?
Resolution:
The top latch for a Fire rated surface vertical rod device is part #650375-00 which replaced the old part #F588.:
Is there a Fire-Rated 33A Rim device?
Resolution:
The Von Duprin 33A/35A rim narrow style exit device is only for non rated openings and fire rating is not available with this device. The Falcon F24-R is a narrow style fire rated exit device T...:
What would the 904H stand for on a Falcon Monarch exit device?
Resolution:
The "904H" is a UL Panic label that is placed on the centercase of the Falcon/Monarch Panic device.:
How thick of door will the standard 24/25 series device mounting package work with?
Resolution:
Standard mounting packages are only for a 1 3/4" thick door. Door thickness other than 1 3/4" need to be specified when ordering the device.:
What is the difference between normally open and normally closed?
Resolution:
In a push button type switch (RX or LX), in which the contacts remain in one state unless actuated, the contacts can either be normally open (abbreviated "n.o." or "no") until closed by o...: