Allegion
Terms of Use
Privacy Policy
Frequently Asked Questions
Ask your question
Entering your question as a complete sentence will provide more accurate results than keywords or phrases.
User questions
FAQs
Category List
Von Duprin
Question
Answer
Why is the Von Duprin 55 or 88 series crossbar sagging?
Resolution:
There are a number of reasons the Von Duprin 55 or 88 series cross bar may not operate properly: The hinge case spring lifts both lever arms and the crossbar. To check spring, pu...:
What back plate conversion kit is required for the 88 with the 373L trim?
Resolution:
Attached tables provide the back plate conversion kit for all 88 series Exit devices. 88 Back plate conversion Chart :
What electric strikes are available for Von Duprin rim exit devices?
Resolution:
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...:
What are cycle testing counts for exit devices?
Resolution:
ANSI grade one cycle test is 500,000, grade two is 250,000 and grade three is 100,000.:
Can I order a "one piece" top rod for an 8827 for a 9' door?
Resolution:
8827 vertical rod device is available for 7 or 8 feet tall door standard. 12", 24", 36" and 48" extension rod kits are available for taller doors (8 feet max on fire rated openings). We do no...: