LCN
Question
Answer
Does LCN have a Cam-Action Closer?
Resolution:
A cam-action closer has not been made available by LCN or Falcon so we have to continue to use our track style closers from an aesthetics point of view, or a standard 4000 series closer i...:
Can a Cam Lift hinge be used with LCN closers?
Resolution:
Cam Lift hinges can only be used with LCN door closers that have a "Regular" or "Reg hold Open" style arm. Manual Closers:Maximum lift dimension is 3/4".Can not be use (H)EDA, CUSH, or T...:
What size Allen wrench is used for Closer adjustment?
Resolution:
LCN does not supply Allen wrenches. The size allen wrenches that LCN uses, are standard sizes that every installer will have in their tool kit. 3/32" Allen wrench for adjusting&...:
Comment on using a Door Closer on extremely Heavy Doors.
Resolution:
I would like to add, this would be like trying to control a bank vault door. The inertia because of the weight is so high that controlling the door is the issue. When a person opens such a door and...:
Are Lead Lined covers needed for LCN Closers?
Resolution:
The determination was made that Lead Lined covers are no longer needed for the LCN product line, see below Marketing/EHS document. Lead Lined cover discontinuation letter :