When are Panic Devices required?
Resolution:
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...:
What distance from the floor for Panic hardware meets ADA
Resolution:
ADA compliance is considered 15" to 48" from the floor for Push or Pull side hardware.THIS IS REFERENCE ONLY. Please contact your local AHJ or Von ...:
Is there an Allegion blog for hardware or code related topics?
Resolution:
Yes.See www.idighardware.comThis is a blog on fire, life safety, and all things exit hardware.:
Can you convert an exit device to AX?
Resolution:
No, you can not field convert an exit device to AX. The AX device has a unique internal baseplate that is not sellable. The AX product also bears a unique UL label. Note:...:
Are the 3CB1 hinges fire rated?
Resolution:
Per the 2016 edition of NFPA 80, the only restrictions for using spring hinges in a UL Listed fire door application are “at least two shall be provided” per 6.4.3.1.1.2, must be “Grade 1” per 6.4...: