Question
Answer
How do you install the arms on a 9100 Series Benchmark operator?
Resolution:
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the...:
Can a Cam Lift hinge be used with LCN closers?
Resolution:
Cam Lift hinges can only be used with LCN door closers that have a "Regular" or "Reg hold Open" style arm. Manual Closers:Maximum lift dimension is 3/4".Can not be use (H)EDA, CUSH, or T...:
Comment on using a Door Closer on extremely Heavy Doors.
Resolution:
I would like to add, this would be like trying to control a bank vault door. The inertia because of the weight is so high that controlling the door is the issue. When a person opens such a door and...:
What does the term "Reveal" mean?
Resolution:
Reveal is the distance or measurement from the face of the door (in closed position) out to the face of the frame or trim. See here for image of Push side reveal. See here for ...:
How deep of a reveal will an 8200 Falcon Operator accommodate?
Resolution:
The maximum reveal for an 8200 Falcon Operator is: 8230 (pull side) -- 1/8" 8240 (push side) -- 6" The Benchmark long rod and shoe (9140-79LR) can be use with the Falcon 8242 for reveal from ...: