Question
Answer
What configuration cards can I use with X02_50 and later or X04_50 and later?
Resolution:
XceedID readers contain a configuration memory map. The values in this memory map dictate how the reader behaves, what card types it reads, type of output (CSN versus secure sector), keypad formats...:
Can I use CD and ALK on a 98/99 series Von Duprin?
Resolution:
Standard 98/99 exit alarm ALK devices are available with cylinder dogging option as of October, 2011. The device can be ordered standard with cylinder dogging and exit alarm ALK opti...:
Can a Senior Swing 2850 or 2860 be used on a Double Egress (DE) door?
Resolution:
The overhead concealed operators (2850/2860) will not work on a Double Egress frame because the doors are not in the same plane. You will have to use the surface mount (9553 / 9563) on Double Egres...:
Where do I put the Active Sync directory path so that my door files are sync with my PDA on Schlage Express?
Resolution:
To change your Program Files folder for SMS Express Open Schlage Express go to Settings and select Program Settings. Go to the Programming tab Click on Locks will be programmed with a Pockect ...:
Is the Falcon FSE/FSA 510 L trim available in 12 volts DC?
Resolution:
The FSA/FSE 510L trim is only available in 24Vdc.:
What cylinder is used for the Falcon 510L and 510L-NL trim?
Resolution:
The Falcon Monarch 510L and 510L-NL trim will accept either a 1 1/4" Mortise cylinder with a straight cam or a 1 3/8" Mortise cylinder with a straight cam using the blocking ring provided with the ...:
Does Von Duprin offer an exit device for exterior use?
Resolution:
Most Panic devices are not designed for exterior applications. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish an...:
Can the 8200 power an EL panic device?
Resolution:
The 8200 can not supply the power needed on an EL dev ice. The EL device requires a Von Duprin PS914-2RS or PS914-4RL power supply or the older Von Duprin PS873-2 or PS873-4TD models.:
What took place of the CM 993 lock?
Resolution:
The Von Duprin CM993 Computer Managed trim was used with 98/99 series exit device and is no longer available. There is not a direct replacement for CM993 trim. AD200/400-993 series are the clo...:
What is the difference between the Senior Swing 9540 and 9530 Series power operators?
Resolution:
The 9542 is the single door operator that mounts on the "push side" of the opening with a REG arm. The 9531 is the single door operator that mounts on the "pull side" of the opening with a STD arm...:
«