What are the benefits of E7500 and E996L-M?
Resolution:
Both E7500 mortise lock and E996L-M provide electrical control of the outside trim. The E7500 mortise lock offers two monitoring switches that would not be available on the E996L-M trim. They moni...:
What is the replacement for the Von Duprin 7321 keypad?
Resolution:
The VD 7308/7311/7321/7322 were replaced by the KP212 Von Duprin 7311 and 7321 key pads were discontinued and there are not direct replacements Von Duprin no longer sells key pads, contact Schl...:
Will a Von Duprin Chexit device automatically rearm itself after a fire alarm clears?
Resolution:
The Von Duprin Chexit device will not automatically rearm itself after a fire alarm clears. After a Fire Alarm has triggered the Von Duprin Chexit device, the device must be manually reset&nb...:
Where does the 8310-877 safety sensor attach to the Senior Swing controller?
Resolution:
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...:
Can I use a 4040SE with a Glynn Johnson 100S?
Resolution:
Mounting with GJ90 Series Stop: If the 4040SE is mounted on the"Pull Side" of the door, (requires a 4040SE-18 drop plate). Holes will need to be drilled in the drop plate to clear the GJ900 thru...:
Need support on a battery operated old hotel swipe card lock called Intellis.
Resolution:
This is a discontinued product no longer support. This product rights were purchased by Westinghouse, (800)-227-1667.:
Can RG-27 be used on a top rod?
Resolution:
Yes, you could use the RG27 on top rod but we recommend RGO. The RG27 is a latch and rod guard and the RGO is a rod guard only. A latch guard is not needed for top latch, only for bottom latch.:
What Ives pivots are typically used with the LCN 6030 closers?
Resolution:
The 6030 door closer can use any of the Ives 7250 Center Pivot sets with standard templating. You will use both top and bottom pivot portion of the Ives Center Pivots. The 6030 "does not" act as t...:
What is the replacement for an LCN 1070?
Resolution:
The P1070 was replaced with the 1261 Rw/PA.The 1260 arm can be used as a replacement arm for the discontinued 1070.The P1070 arm can be used on a replacement 1260 body to maintain the origina...:
How do you change a 9130 Benchmark to a 9140 Benchmark?
Resolution:
The only difference between the 9130 and 9140 Benchmark operators are the arms.To convert a Benchmark 9130 (pull) to a 9140 (push), order a 9140-3077 push arm assembly for revea...:
«