How does the Von Duprin 98/99 rim or vertical rod exit device with lever trim convert from L to L-NL function?
Resolution:
To convert the Von Duprin 98/99 Rim or Vertical (Rod or Cable) Exit Device with functional lever (996L-R/V) to act like a rigid lever (996L-NL-R/V) with key over ride follow these steps: R...:
Does the 4600 series operator have a Push N Go feature?
Resolution:
The 4600 Series operator does not have a Push N Go feature. The LCN operators with a Push N Go feature are the Senior Swing, Benchmark, and the Falcon 8200 series.:
Why would a 9927 bottom rod drag?
Resolution:
Following could cause the bottom latch on 98/9927 exit device to drag. Bottom rod is too long. Adjust bottom rod per instruction sheet 911375. Top latch controls the bottom latch. ...:
What strike is required when using the 2670 Guard-X on a pair of doors?
Resolution:
With a mullion: Use the standard strike 267 With no mullion and inactive leaf being held closed with flush or surface bolts: Use the 2609 double door strike :
What is a MS 700 from Von Duprin? Is there replaceable parts?
Resolution:
MS776 and MS774 were door position switches offered by Von Duprin. The same switches are now sold by Schlage as 7764 and 7766.:
Will the 9100 series Benchmark III power an electric strike?
Resolution:
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...:
What is a 62A shoe used for?
Resolution:
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.:
Are LCN Closers Fire Rated?
Resolution:
All LCN closers have UL listings and are in compliance to UL10C, and are Fire Rated for up to 3 hours.With regards to the 3 hour rating, all products in this category are considered 3 hou...:
What are the dimensions of the push plate boxes?
Resolution:
Push plate boxes are available, see user guide here. For all 8310 Mounting Box dimensions/templates/drawings see here. :
Which LX switch do I use on a QEL33A/35A/98/99 devices?
Resolution:
The QEL33A/35A/98/99 devices will use the standard LX switch, 050254 for 3' devices and 050255 for 4' devices field installed and 050252 for 3' devices and 050253 for 4' devices fact...:
«