Question
Answer
What is the difference between a 4110-18, and a 4110-18 CUSH drop plates?
Resolution:
The 4110-18, and 4110-18 CUSH drop plates are identical. The difference between a 4110 EDA, and a 4110 CUSH is the templating on the door. That is why you order them differently, to...:
Why is my Senior Swing so hard to open manually?
Resolution:
A Senior Swing operator can be hard to open manually if "Power Boost" feature is turned on, and programmed to the Cn (continuous) setting. To make the door easy to open manually, turn the "Power ...:
What part is required to add a sequencing feature to a 7902/7982 control box?
Resolution:
The sequence card part number is 3426 and plugs in the "S" slot of a control boxes right next to the 10 pin terminal strip. The 7902/7902ES or 7982/7982ES can be converted to a 7902S/7902SES or 79...:
Does Falcon provide an On/Off switch for the 8200 series operator?
Resolution:
The Falcon 8200 operator is not available with a factory supplied on/off switch. If required, it must be supplied by others.:
How do you get the digital read out to light up on the Senior Swing Control Box?
Resolution:
There is a total of 4 red buttons on the front of the Senior Swing control box. To turn on the display, press and hold any 2 of the 4 red buttons at the same time for approximately 3-5 seconds. Y...:
What electric strike can be used on a pair of doors with an L9000 lock?
Resolution:
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.:
Is the 3130 Series closer Fire Rated?
Resolution:
The 3130 Series closer is UL listed- Fire Rated (UL-10C) for up to 3 Hr. The Door and Frame Manufacturer needs to be contacted to verify their Door/Frame rating would not be ...:
Can a 9500 series operator on the push side be used with Cam lift hinges?
Resolution:
The Senior Swing will work with Cam Lift Hinges as a PUSH SIDE MOUNT 9542/9553/9563 only. Maximum 3/4" lift. Maximum 15 pounds force to push door up the Cam Lift Hinge. Cam Lift Hinges WILL NO...:
What is the part number for the Spring Cush block?
Resolution:
The part number for the Spring Cush block assembly is: model number-3080. EXAMPLE: 4110-3080:
Do I have to use the 388 to get NL-OP on a 33A/35A series device?
Resolution:
The 388 Cylinder Control is required for the NL-OP function on a 33A/35A series exit devices.The 110NL is used on 22 and 98/99 series exit devices not 33/35A series devices.The 33A/35A de...:
«