Can the 8200 Series operator power a electric strike?
Resolution:
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device.:
Can the fluid in an LCN door closer be filled out in the field?
Resolution:
The fluid in an LCN closer must not be refilled in the field. See attached Warranty and Repair Communication :
Can you replace a regular arm with a hold open with out moving the door closer?
Resolution:
Yes, as long as you stay with the like style arm. Example: replace an RW/PA with HW/PA, replace an EDA with HEDA, or replace a CUSH with HCUSH.:
Does Schlage make a 1 1/2" backset?
Resolution:
Backsets are only available in the following lengths on specific product lines: 2 3/8", 2 3/4", 3 3/4", 5", and as a special over 5" up to 42" :
What is an LCN Touchplate 2500B relay?
Resolution:
The Touchplate Relays were lighting control relays, used in automated (computer/building controlled) lighting systems in large buildings. They are an obsolete LCN product. LCN only made these relay...:
What is an LCN 1521 closer?
Resolution:
The 1521 series closer was obsoleted in 2006. The closer is still in production today but it is the 4031 non-handed series closer. The 4031 non-handed closer is a direct retrofit ...:
Are parts available for the EPT-2 or EPT-10?
Resolution:
The only parts available for electric power transfer EPT2/10 are the back boxes through Engineering Specials. Part number 01-508-00.:
Are the wires on a Von Duprin 6000 series electric strike polarized?
Resolution:
The wires on 6000 series electric strike solenoid are non polarized.:
What is the difference between a 4110-18, and a 4110-18 CUSH drop plates?
Resolution:
The 4110-18, and 4110-18 CUSH drop plates are identical. The difference between a 4110 EDA, and a 4110 CUSH is the templating on the door. That is why you order them differently, to...:
Why is my Senior Swing so hard to open manually?
Resolution:
A Senior Swing operator can be hard to open manually if "Power Boost" feature is turned on, and programmed to the Cn (continuous) setting. To make the door easy to open manually, turn the "Power ...:
«