PIM-485-OTD RS Cloning Procedure
Resolution:
See attachement below on cloning procedure: PIM-485-OTD RS Cloning Procedure :
PIM400-485 appears to lose Link with lock immediately after a power cycle
Resolution:
Whenever a PIM400-485 has power applied, it will do its normal "Power-On Reset". This reset will momentarily erase the currently linked lock data that is normally stored in the PIM400-485 a...:
What is the purpose of the 1260-18QF?
Resolution:
The 1260-18QF mounting plate is used to adapt the 1260 closer to the obsolete 1370 mounting hole pattern.:
How does the 98-2 or 99-2 double cylinder function affect the outside lever trim?
Resolution:
Double cylinder (-2 or -2SI) features an inside key cylinder which locks or unlocks the outside trim and an outside key cylinder which retracts the latch bolt only (Night latch function). Thi...:
Are you able to mount a cylinder directly to the outside of the door when using a 33A device?
Resolution:
You must use the 388 trim plate assembly with cylinder to operate the 33A device.:
Are you able to operate a mag lock or shear lock off of the 873-4TD card?
Resolution:
You can operate up to four maglocks off of the 873-4TD option board.:
What is the minimum opening that a Chexit 4' device can be cut down?
Resolution:
The Von Duprin CX 98/99-4 feet Rim devices on single doors with 5/8" stops and the standard 299 roller strike can be field sized to fit a minimum of 40.2" door opening. This an...:
Procedure to Initialize a New Red Programming Key into a PED-1000 or PED-500
Resolution:
Procedure to Initialize a New Red Programming Key into a PED-1000 or PED-500. For this procedure utilize a user key that is valid in the unit, a new red programming key, and an HHD. 1. Pr...:
PDA's and DST patch compatibility for HHD
Resolution:
The DST patch from Microsoft is not compatible with mobile PDA on Windows Mobile 4 manually time changes will be required. On units running Windows Mobile 5 or higher, the DST...:
What wire gauge and run is recommended for Von Duprin electric latch retraction EL device?
Resolution:
:
«