Question
Answer
What is the resistance reading of the coil on a GF3000 Mag lock?
Resolution:
The coil should read 14 ohms between the white and red wires at the coil.:
Is the door cord UL listed?
Resolution:
The door cords are not UL Listed. They do not require any holes drilled through the door so that is why they are not rated:
What is the door thickness available for the FE210?
Resolution:
1-3/8” to 1-3/4” standard. 1-3/4“ to 2 optional. Must be specified:
Is the attached hammer available separately for the 740 series Break Glass?
Resolution:
No, the hammer is not available separately.:
In Schlage Express, what does “Delete with audit and alarm” mean?
Resolution:
This means that an audit will take place, the door will not unlock, and an alarm will sound. It is a credential function that can be used for example, when an employee is terminated and is no...:
Glynn Johnson 90 Overhead End Cap Upgrade 2015
Resolution:
This bulletin announces the move away from the old painted zinc end caps (829644622) on the 90 Overhead series and the transition to a new style of overhead end cap (831001-00). :
Is the tailpiece the same for the AD locks as for the ND or AL series for the Schlage FSIC?
Resolution:
The tailpieces are not the same for the lock series as they all have different lengths for each lock series. :
How to identify a lever insert between the AL and old D lever locks.
Resolution:
The AL and Old D series lever insert identification chart can be found here.:
What is visual key control (VKC) on keys?
Resolution:
Visual Key Control (VKC) refers to stamping the key symbol on the bow of the key. This makes identification fast and convenient. The disadvantage is that lost or stolen keys can potentially b...:
Can you use a CT5000 with SRT-100 and a keypad reader to program ibuttons into the CT5000?
Resolution:
You can connect the SRT-100 and a Schlage keypad reader with 8-bit burst to program the ibuttons into the CT5000 without using express software.:
«