Answer
How long does it take to install a L Series mortise lock?
Resolution:
Typical installation by an experienced Schlage L lock installer on a door correctly prepped for the Schlage L-Series function could take 10 to 20 minutes. Many outside variables can change the amo...:
Does LCN still make a 4010SE / 4110 SE?
Resolution:
The LCN 4010SE / 4110 SE series are obsolete, and on longer available (discontinued around Aug 1995). They were replaced by the 4040SE series.The 4010SE / 4110 SE track is replaced w...:
Will Schlage make a cylinder in another vendors keyway?
Resolution:
Schlage only offers a limited number of keyways that match the BEST sections. Available in keys and cores.Specify keyway using the B suffix: AB = A, BB=B, CB=C, DB = D, DDB=DD, EB = E, FB = F, GB =...:
Can you order the danmark lever separate?
Resolution:
The danmark trim was not available as a separate item, danmark trim was only available with a complete lock.:
What electric strikes are available for Von Duprin rim exit devices?
Resolution:
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...:
What causes a Senior Swing door to hang open and not close?
Resolution:
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...:
Adding locks to Legacy PIB-4D- additional locks not recognized.
Resolution:
When adding another door to the legacy PIB-4d, You must change the S1 dipswitches 11 & 12 Number Dip11 Dip12 of l...:
CDT with Firefox browser does not work
Resolution:
WA-PIM-485 utility CDT will not open Using Mozilla Fire Fox or Google Chrome, it is not compatible with those browsers.You must use Internet Explorer to open CDT.The current CDT version 3.04 will w...:
Card not reading into Schlage Express, getting error message "System error / unable to open specified file"
Resolution:
Check com port selection either on wrong port or set to NONE Select menu item - Program settings Select credentials and devices tab Check serial port selection in lower left of window....:
What is the maximum reveal for a regular arm 4642 operator?
Resolution:
Max. reveal for a 4642: 4640 Regular arm -- 4.5" 4640 Long arm -- 8" 4640 x ST-3088 ( custom made - extra long rod) -- 8" to 11" No special mounting instructions required, just standard templ...:
«