Question
Answer
How long does it take to install a L Series mortise lock?
Resolution:
Typical installation by an experienced Schlage L lock installer on a door correctly prepped for the Schlage L-Series function could take 10 to 20 minutes. Many outside variables can change the amo...:
Does LCN still make a 4010SE / 4110 SE?
Resolution:
The LCN 4010SE / 4110 SE series are obsolete, and on longer available (discontinued around Aug 1995). They were replaced by the 4040SE series.The 4010SE / 4110 SE track is replaced w...:
Will Schlage make a cylinder in another vendors keyway?
Resolution:
Schlage only offers a limited number of keyways that match the BEST sections. Available in keys and cores.Specify keyway using the B suffix: AB = A, BB=B, CB=C, DB = D, DDB=DD, EB = E, FB = F, GB =...:
Can you order the danmark lever separate?
Resolution:
The danmark trim was not available as a separate item, danmark trim was only available with a complete lock.:
What electric strikes are available for Von Duprin rim exit devices?
Resolution:
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...:
What causes a Senior Swing door to hang open and not close?
Resolution:
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...:
Adding locks to Legacy PIB-4D- additional locks not recognized.
Resolution:
When adding another door to the legacy PIB-4d, You must change the S1 dipswitches 11 & 12 Number Dip11 Dip12 of l...:
CDT with Firefox browser does not work
Resolution:
Current version CDT download link: CDT v 3.04:
Card not reading into Schlage Express, getting error message "System error / unable to open specified file"
Resolution:
Check com port selection either on wrong port or set to NONE Select menu item - Program settings Select credentials and devices tab Check serial port selection in lower left of window....:
What is the maximum reveal for a regular arm 4642 operator?
Resolution:
Max. reveal for a 4642: 4640 Regular arm -- 4.5" 4640 Long arm -- 8" 4640 x ST-3088 ( custom made - extra long rod) -- 8" to 11" No special mounting instructions required, just standard templ...:
«