Question
Answer
Can the 268-10 or 320 Maglocks without circuit boards be wired for 12 or 24 VDC
Resolution:
(12VDC: Red ties to positive(+), White wire ties to negative(-), Black & Blue wires tied together) (24VDC: Red and Black wires tied together connect to positive(+), Blue and White wires t...:
Can Drywall Slip-on frames be welded?
Resolution:
Drywall Slip-on frames are recommended and designed to be installed as KD (Knock Down) assemblies and not recommended to be welded (SUA). If a DW-Series or K-Series is welded prior to installa...:
Is the Ives 8190 for 2 1/4" thick doors an engineering special?
Resolution:
The 8190 can be order as a standard for 2 1/4" door thickness. Specify the door thickness to get proper mounting hardware.:
Is the 900-4RL card required when using a Beesam auto operator?
Resolution:
Depends on the application. If the Beesam Auto Operator you are using has the timing relays and output contacts available in it you could possibly use the 900-2RS option card. This is d...:
What is the 3041 electric strike?
Resolution:
Von Duprin had an older series of electric strikes that preceded the current 6000 offerings. The 3041 was replaced by the 6213 electric strike.:
Is there a way to make EL devices quieter?
Resolution:
You can't make the EL device quieter. The inrush of current causes the plunger and solenoid to make noise. A quieter option would be motorized electric latch retraction. Von Dupri...:
Explain the function of the L9486.
Resolution:
:
What is the difference between the 5BB1 hinges and 5BB1HW hinges?
Resolution:
The 5BB1 hinge has a material thickness of 0.134", where the 5BB1HW hinge has a material thickness of 0.180".:
How do you sequence two of the Senior Swing 9540, 9530, 9550, or 9560 operators?
Resolution:
The current LCN 8310-845 Relay and door Sequencer module is required to sequence two Senior Swing operators. The 8310-845 will need to be programmed to "Function 65" for the sequencing featu...:
Can a Senior Swing 9550 be mounted on an unequal pair of doors?
Resolution:
"PUSH SIDE" application: Minimum 52" wide pair, with neither door being less than 21" wide. "PULL SIDE" application - For Product Shipped...:
«