Question
Answer
What is an A, B, C and D label fire door?
Resolution:
A = 3 hour (180 minute) fire ratingB = 1.5 hour (90 minute) fire ratingC = 0.75 hour (45 minute) fire ratingD = 0.5 hour (30 minute) fire rating:
If you remove jumper off the 900-FA board to install onto the 900-2RS should they give the jumper to the customer so they have it?
Resolution:
The removed jumper is left inside the power supply enclosure at the factory so it would be available if the FA card is ever removed.:
several red flashes on prox cards on cm locks; No access
Resolution:
Red LED blinks 2-3 times after a valid credential is presented.Out side of time zone.Verify corrected time on lock ensure cards are in a valid time zone.:
What is the maximum number of users on an AD-200 lock
Resolution:
AD-200 5000 users, 5000 audits CO-100 500 users CO-200 2000 users 2000 audits KC-2 1000 users, 1000 audits CM (Silver) 1000 users, 1000 audits:
Can the 268-10 or 320 Maglocks without circuit boards be wired for 12 or 24 VDC
Resolution:
(12VDC: Red ties to positive(+), White wire ties to negative(-), Black & Blue wires tied together) (24VDC: Red and Black wires tied together connect to positive(+), Blue and White wires t...:
Can Drywall Slip-on frames be welded?
Resolution:
Drywall Slip-on frames are recommended and designed to be installed as KD (Knock Down) assemblies and not recommended to be welded (SUA). If a DW-Series or K-Series is welded prior to installa...:
Is the Ives 8190 for 2 1/4" thick doors an engineering special?
Resolution:
The 8190 can be order as a standard for 2 1/4" door thickness. Specify the door thickness to get proper mounting hardware.:
Is the 900-4RL card required when using a Beesam auto operator?
Resolution:
Depends on the application. If the Beesam Auto Operator you are using has the timing relays and output contacts available in it you could possibly use the 900-2RS option card. This is d...:
What is the 3041 electric strike?
Resolution:
Von Duprin had an older series of electric strikes that preceded the current 6000 offerings. The 3041 was replaced by the 6213 electric strike.:
Is there a way to make EL devices quieter?
Resolution:
You can't make the EL device quieter. The inrush of current causes the plunger and solenoid to make noise. A quieter option would be motorized electric latch retraction. Von Dupri...:
«