Does Von Duprin sell a cover plate for an EPT Prep?
Resolution:
Von Duprin doesn't sell a cover plate for EPT2/10 prep.:
Can 24 volts be run to a 12 volt 6000 series electric strike solenoid?
Resolution:
You can't run 24VDC into the 12VDC electric strike, over voltage such as this will cause the solenoid to heat up and damage the solenoid. You must change to a 24V solenoid, part number 050240-00.:
What special template (ST) is used to get a 4040 closer without a spring, for checking only?
Resolution:
ST-2687 is for a closer that is assembled without a spring. For any large body closer (4010, 4020, 4110, 4040XP, 2010, 5010, and 2210 series closers), not available on the 1460/1460T, 1...:
What is the power draw of a Senior Swing series operator?
Resolution:
The Senior Swing (2800/9500) Series operator has a 120VAC @ 2.5 Amp current draw for a single door (2811/9531/9542) or simultaneous pair(2853/9553). The independent pair units (2863/...:
Will the Von Duprin 6210 electric strike operate with the MA series locks?
Resolution:
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...:
Can a Von Duprin ALK Device be hooked up to an external horn and two key switches?
Resolution:
ALK can not be connected to an external horn but it can be connected to multiple key switches.:
what is the wiring to by pass the electronics board for to 390+ magnetic lock
Resolution:
12VDC - red/black = positive blue/white = negative 24VDC - red = positivewhite = negative Connect blue/black:
Can you power a electric strike from the 7900 control boxes?
Resolution:
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...:
Why would a Senior Swing door slam shut?
Resolution:
The Senior Swing has a built in circuit that controls closing speed through the motor. If the door is slamming, there must be a broken gear in the gearbox and the gearbox will need to be replaced.:
What is the minimum stile for a 1790?
Resolution:
Minimum stile for the 1790 device is 1-3/4" per Falcon-D Catalog.:
«