Can you wire up two QEL devices to O1 of the 900-2Q board on PS902-2Q?
Resolution:
Two QEL devices can't be wired up to O1 of the 900-2Q board. PS902 is a two amp power supply and each QEL device has a 2 amp inrush. Connecting two QEL devices to the same output O1 draw...:
Does the EL25-R come with an EL cable like the EL98/99's?
Resolution:
The EL24/25R comes with an EL cable.:
Are Schlage AL series products handed?
Resolution:
The AL series product line does not use any parts that requires prior knowledge of the door handing. :
What is the current draw of a CT-5000
Resolution:
500mA at 12 or 24 VDC:
What powder coat best matches US10B for a closer?
Resolution:
The closest powder coat finish by LCN is Dark Bronze (BHMA 695).:
Will the 6210 FSE DS operate if the DS switch is not used?
Resolution:
The 6210 electric strike will lock/unlock even if DS option is not used.:
How is the 6211 ordered for a wood frame?
Resolution:
Specify 6211WF for a wood frame.:
Does Von Duprin sell a cover plate for an EPT Prep?
Resolution:
Von Duprin doesn't sell a cover plate for EPT2/10 prep.:
Can 24 volts be run to a 12 volt 6000 series electric strike solenoid?
Resolution:
You can't run 24VDC into the 12VDC electric strike, over voltage such as this will cause the solenoid to heat up and damage the solenoid. You must change to a 24V solenoid, part number 050240-00.:
What special template (ST) is used to get a 4040 closer without a spring, for checking only?
Resolution:
ST-2687 is for a closer that is assembled without a spring. For any large body closer (4010, 4020, 4110, 4040XP, 2010, 5010, and 2210 series closers), not available on the 1460/1460T, 1...:
«