Answer
Can a 1 3/4" thick panel be used in a fire rated transom frame with a transom bar?
Resolution:
Transom panels are available in the following constructions: 1 3/4" thick panels with interior construction similar to an L-Series door installed into a frame either Without a transom bar - r...:
What replaced the PS873-K-2-BB?
Resolution:
PS914-K-2RS-BBK replaces the old PS873-K-2-BB.:
Why is my PS873 outputting 27 volts?
Resolution:
If PS873 power supply provides more than 26.4VDC replace the power supply with PS914 power supply.:
Do we still sell a pullman bottom latch for the old 18-V?
Resolution:
Falcon does offer a pullman style (less deadlocking, less retention) top latch for use with the Falcon 24-V, 25-V, the Falcon/Monarch 19-V, and the discontinued Falcon/Monarch !7-V, 18-V, and XX-V ...:
What screw pack comes standard with LCN closers?
Resolution:
The standard screw pack for most LCN (mechanical) closers is the SRT screw pack.:
What is the maximum glass light size on a 90 min (1 1/2 hour) fire rated door?
Resolution:
Standard listed wire glass: one (1) light with 100 in2 per door leaf max.Firelite or other appropriately listed glass:• FM maintains one (1) light with 100 in2 per door leaf max.• UL &...:
Can you hardwire a 2670 and not use the PT-790?
Resolution:
The PT-790 is the pluggable power supply and is required if you want to hardwire the 2670 Guard X.:
What type of core will a lock with the cylinder suffix "J" accept?
Resolution:
The full size interchangeable cores or FSIC from Schlage.:
What is the part number for a SFIC core from Falcon?
Resolution:
Regular Core (suffix keyway to number) Description Uncombinated Combinated 6-Pin 7-Pin 6-...:
Can we have 9927-F LBR and 9975-F on a paired opening?
Resolution:
This combination is not available. The 98/9927-LBR-F has only been UL tested as vertical by vertical combination on pairs of fire rated doors.:
«