Can I add Hex Dogging to my EL33/35A or EL98/99 series exit device in the field?
Resolution:
This would require a HD EL Conversion Kit 050384 for a 3' device or 050385 for a 4' device. You will also need a 050117-XX 35A/98 or 050114-XX 33A/99 Hex Dog Conversion kit. :
Are the Von Duprin 6000 series electric strikes rated for continuous duty?
Resolution:
All of Von Duprin 6000 series electric strikes have continuous duty solenoids either 12 or 24VDC.:
On a 679-05WD door postion switch, where does this need to be located on the door?
Resolution:
Typical positioning would be a few approximately 6 inches above the latch on the door edge. Alternative location could be the door top edge.As far from the hinge side as possible. :
Will the end cap from a 672 or 692 REX Touch bar fit the old 671 Touch bar?
Resolution:
NO: End caps for the 672 & 692 REX Touch bars are not compatible with the 671 Touch bar.:
GF3000 Power Supply
Resolution:
At 12 vdc 2 GF3000's will need 1.8 amps , lvery close to the PS902 supplies limit. If running at 24 vdc technically 4 units would draw 1.8 amps . A limit of 3 would be bet...:
Can the Von Duprin EL option be added to any existing 98/99 device?
Resolution:
The Von Duprin EL option can be added to any existing 33A/35A, 98/99 series exit devices. :
Can a panic device be converted to a fire-rated device in the field?
Resolution:
A standard exit device can't be modified to a fire rated exit device. In order to get a product with the UL fire label, a new device must be purchased. This is a UL requirement.:
Can I make a wireless activated 4640 operator work as alternate action?
Resolution:
The 8310-865 RF receiver contacts (N.O. and COM) would connect to terminals 15 & 17 (the alternate action input) on the 4600 operator. The first activation would open the door, the s...:
What is LCN replacement part number for a Dor-O-Matic number 81007-90x?
Resolution:
81007 is the old DOM number for a Sr Swing Motor gearbox. The -90x indicated the Hand, a -901 is RH and a -902 is LH. If you have a 81007-901 - The LCN replacement part numb...:
What functions are available for the E996 trim?
Resolution:
E996 trim can be ordered FS or FSE, lever trim must be either L or L-BE. In both situation (E996L or E996L-BE), the electronics lock/unlock the lever. The E996L trim allows for the inst...:
«