Question
Answer
Does Falcon make a plate to cover holes when the door is prepped wrong?
Resolution:
These items are not available from Schlage or Falcon. There are third party companies such as Don-Jo or Pro-Lok that manufacture cover plates.:
Do we have special templates (ST) for the Falcon line of door closers?
Resolution:
The Falcon Closers are not available with special templates. If a special application is required, then we recommend to use the LCN brand and any associated special templates.:
What is the part number for the Falcon 8200 (8230/8240) series operator control box?
Resolution:
The Falcon 8200 Series control box can be ordered as either an 8230-3462 or an 8240-3462. They are the same part.:
What special template (ST) is used with a 4040 closer, PA mount and a 18" door width?
Resolution:
Special Template ST-2338 is used to mount a 4040/4040XP closer mounted Rw/Pa on an 18" door.:
What is the minimum rose dimension that can be used with a Steelcraft 61L lock preparation?
Resolution:
The minimum rose that can be used on the 61L (ANSI/BHMA A156.115.18) preparation is 3 7/16".Steelcraft's 61L lock prep (often referred to as the "Squashed Turtle lock prep") is designed for Bored L...:
What replaced the 12-274 deadbolt?
Resolution:
There is no direct replacement. This deadbolt was the standard bolt provided for the BC100-Series which was discontinued in 2007.:
What are security jamb anchors?
Resolution:
Security anchors are used in DW/K frames located directly above or below strike preparation on door side of frame. Because there are only two points of anchoring, the compression anchor near the ...:
Can an auto operator be installed on a Dutch door?
Resolution:
Yes, an automatic operator can be installed on a Dutch door. The operator must be installed on the top leaf of the Dutch door. Only the top half will open unless the top and bottom leaves (se...:
Will the 9550 series Senior Swing work with a strike and auto flush bolts?
Resolution:
The 9550 series Senior Swing WILL NOT work on a pair of doors with Electric Strike and auto flush bolts because you cannot sequence the door openings with a 9550 simultaneous pair operator.&nb...:
Does the EL and the QEL install the same on the door?
Resolution:
Both the EL and QEL(A) can be mounted the same on the door.:
«