Can the 5100 electric strike be used with mortise locks?
Resolution:
:
Is the Windstorm (WS) device handed?
Resolution:
The Windstorm device is handed. It is reversible by ordering and installing the appropriate handing of center case. The center case is handed because both vertical rod linkages must m...:
What special template (ST) is used with a 4110 closer and GJ90 series?
Resolution:
ST-2730 is used with a 4110EDA closer and GJ901-904 overhead stop.This can only be used with GJ901-904.If a drop plate is required, a 4010-18 drop plate would be used (A 4110-18 drop plate can not ...:
What can be ordered if a no lip strike is required for the L9000?
Resolution:
The L-Series standard strike is the 10-072 and the available lip lengths are listed below. 7/8" (Flat or straight lip) See picture below.1"1 3/16" (Standard for 1 3/4" doo...:
What is the Falcon restricted keyway process for new end users?
Resolution:
A PO from a distributor with a letter of authorization from the end user.:
Does the wire size of an EPT affect the operation of an EL device?
Resolution:
Since most wire transfer devicesĀ such as an EPT or electric hinges cannot provide large gauge wires, we take the small gauge wire into account when determining the overall wire sizeĀ for the device....:
Can I buy a fire rated baseplate and replace it with my standard baseplate assembly for my 99 Rim?
Resolution:
The standard non rated device can not be modified to a fire rated device. You would need to replace the device so you would have a device with the fire-rated label.:
Is the Ives 112HD/224HD hinge rated for an A label (3 hours)?
Resolution:
All of the Aluminum 112HD/224HD geared hinges are rated upto 90 minutes, B label.:
Can the existing 9927/9947/9948 devices be cut to fit a 24" leaf?
Resolution:
No, the existing 98/9927/F, 98/9947/F and 98/9947/F devices can't be cut to fit a 24" leaf door.:
What is the minimum opening for a QEL 98/9927 or 98/9947?
Resolution:
The minimum door opening for 98/9927 and 98/9947 on a pair of doors would be 29" for a 3' device and 35" for a 4' device.:
«