Zentra - Deleting and Re-Adding Schlage RCs

If a Schlage RC commissioned to a Zentra site needs to be Factory-Default Reset (FDR) for troubleshooting purposes: 

  1. Factory reset the RC: hold the small black reset button on the back of the reader until two beeps are heard, approx 10 seconds.  

  2. Delete the RC from Zentra in the web platform, or on the mobile Zentra app.

  3. Using the Zentra mobile app, choose “Add Device” and walk through process to add the reset RC back into Zentra.

     

    1. Note: After re-commissioning, the device will need to be added to any access point groups / rules it may have been assigned to before the deletion.


DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.