Wireless PIM-485 Loss of 485 Connection

When using a PIM-485 configured with the RSI protocol and the PIM-485 loses the 485 connection to the ACP Panel, the following result will occur. If the PIM-485 is not polled by the ACP for more then 5 seconds then the WAPM's linked to the PIM will go into degraded mode if enabled, either fail safe or fail secure or use the cache. If no degraded mode is enabled, then the unit will remain in current state and not accept any credentials.