Will a Schlage L9000 fit a Falcon MA door prep?

The Schlage L9000 lock will not fit in a door prepped for the Falcon MA.

  • The mounting post holes are located 90 degrees off from each other on the Falcon MA and the Schlage L9000.
  • On the MA series, the center line of the lever spindle access hole is located 7/32 (6mm) closer to the centerline of the lock.
  • The Schlage L9000 thumbturn prep centerline is 2-3/4" from the centerline of the lever spindle access prep. On the Falcon MA, this dimension is 2-7/16"
  • MA pocket depth requirement is 4.5 and the Schlage L9000 pocket depth requirement is 4.5 (electrified is 4.75)
    • This needs to be confirmed as the MA lock case measures 4.15" and some door manufacturers may not have cut out a depth of 4.5"

DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.