Why does an AD or CO lock get a low indication battery when installed?

If the indication is red 9 times on the right side of the Schlage button, the coin cell may be low or the coin cell insulator was not removed.

If the indication is red 9 times on the left side of the Schlage button, the AA batteries are weak.

Replace AA batteries or the coin.

Remove plastic insulator film from below the coin cell.

YOU MUST PRESS S1 TO REBOOT FIRMWARE - S1 located at 8 o'clock from IPB