Where is factory recommendation for location of an EPT?

EPT installation guidelines are as follows:

  • Recommended location is 6" below top hinge per template
  • Steelcraft will locate the power transfer prep at the Von Duprin recommended template location of 6" below the bottom of the top hinge to the top the the power transfer preparation unless noted otherwise. This applies to both the door and frame.
  • When used with 4 1/2" hinges the locations are as follows:
    • Frame location is 22 17/32" from head to CL of preparation.
    • Door location is 22 13/32" from top of door to CL of preparation.

DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.

Other users ask