When REX is enabled for Schlage RC devices, and set for “Admit”, how does the admit function?

When the REX function is enabled and set to “Admit”, upon use of the REX input trigger (Green and Black wires), the access point will release for the “Latch Interval” set for that device in Pure Access.  

Releasing the trigger early or holding the trigger for longer will not affect this, the door will always unlock for the set latch time.