The correct method (process) for setting the hold open is:

  1. The 4110 HEDA arms are handed, verify correct hand arm. (RH or LH stamped on shoe bracket)
  2. Loosen the hold open nut at shoe bracket.
  3. Opened the door to 5 degrees less than the desired degree of hold open.
  4. Tighten the nut securely. (Make sure also there is not a gap between the shoe and the main arm)
  5. Push door open to engage hold open.
  • 4110 hold open arm part number is --- 4110-3049
  • 4110 hold open adjustment wrench part number is --- T1157