What is the default keypad configuration on an Schlage reader with keypad?


The default format that is enabled by default on the MTK15 is 8-bit burst.
The default keypad configuration is the 8-bit burst.  Should the keypad configuration be changed either to 4-bit burst or 26-bit and the customer wishes to revert back to default, set the configuration to 8-bit burst.
To change the MTK15 keypad configuration format:
 
1)      Power cycle the reader.
 
2)      Within 1 minute from powering on the unit, enter: * 8 8 8 8 9 9 9 9 (The LED will turn green and the keypad will beep three times.)
 
3)      Within 5 seconds, enter the necessary keypad format using the keypad.
A)     4-bit burst -  Enter 0 1
B)     8-bit burst – Enter * 0 (This is enabled by default.)
C)     26-bit Wiegand – Enter # followed by a 3 digit facility code between 000 and 255.
Examples:
·        Enter # 0 9 6 for fixed facility code 96.
·        Enter # 1 2 8 for fixed facility code 128
The LED will turn green and the keypad will beep three times.
 