What does a Factory Default Reset (FDR) do for NDE locks?

FDR will do the following functions:

• Erases audits
• Erases access control programming
• Sets reader configuration to as shipped
• Lock configuration delays to as shipped
Clears Construction mode
 

FDR – will NOT:

• Remove or delete the NDE  from an active ENGAGE account
• Remove firmware updates
 
NOTE:  The RTE (RX) switch (inside lever) is required to be functional to initiate FDR mode
 
To FDR:
Open the battery cover.  Press the button under the pin hole above the batteries.
Press and HOLD FDR button until you hear two beeps and 2 green LED blinks.
 
Turn the inside lever 3 times within 20 seconds-LED will blink red and lock will beep with each turn.
It is complete when you will hear one long beep.
Install cover and connect to lock. 
Click here for the YouTube on resetting an NDE lock.

DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.