What does a Factory Default Reset (FDR) do for NDE locks?
FDR – will do the following functions:
• Erases audits
• Erases access control programming
• Sets reader configuration to as shipped
• Lock configuration delays to as shipped
• Clears Construction mode
FDR – will NOT:
• Remove or delete the NDE from an active ENGAGE account
• Remove firmware updates
NOTE:The RTE (RX) switch (inside lever) is required to be functional to initiate FDR mode
To FDR:
Open the battery cover. Press the button under the pin hole above the batteries.
Press and HOLD FDR button until you hear two beeps and 2 green LED blinks.
Turn the inside lever 3 times within 20 seconds-LED will blink red and lock will beep with each turn.
It is complete when you will hear one long beep.
Install cover and connect to lock.