NDE battery Information

• Batteries: Uses 4(ea.) AA alkaline batteries (provided in the box)
•+6.0VDC typical operating voltage
 
• “Battery Voltage” is available via Audit events –
• Low Battery = 4.4 VDC
•Reported in Audits
•Nuisance Delay
- 6% remaining battery life with smart card reads
-  Approximately 500 remaining read/unlock/lock cycles until critical battery
 
• Critical Battery = 4.0 VDC
•Enters Battery Fail Mode (Fail-Safe, Fail-Secure, Fail As-Is)
 
• “Sleep Current” is reported via Audit events – 
• Power-On-Self-Test (POST) and initiated “Diagnostics” will provide the latest up to the minute readings
• Sleep current for an NDE is typically 100ua (micro-amps)