Low Battery Indication for AD Locks offline - Nusiance Delay

Nusiance Delay: 
Low battery indications: Offline locks

After credential is presented, 9 red blinks of Schlage button (Left = AA, Right = Coin Cell), then normal Green indicator and unit unlocks.

Replace batteries immediately to avoid battery failure. Lock is intended to operate for 500 cycles in low battery condition.

Mechanical override key must be used to unlock the lock.
 
NOTE: IF THE COIN CELL BATTERY IS REPLACED, POWER DOWN THE UNIT, INSERT THE NEW COIN CELL BATTERY, AND THEN RE-POWER THE UNIT. IF YOU REPLACE THE COIN CELL BATTERY WITH THE AA BATTERIES CONNECTED, THE UNIT WILL STILL SHOW THE LOW COIN CELL BATTERY NUISANCE. Also press S1 button after coin cell replacement.

DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.