Is the Von Duprin EPT10 required for CX device?

The wires in the EPT are larger than the wires in an electric hinge and are less prone to breaking. This is why we recommend the Von Duprin EPT10 with CX device but if necessary you may use a door loop or electric hinge.  Note wire size requirements for EPT, door loop and electric hinge in table below.

See attached table for wire run and gauge requirements:

Exit device Wire run & gauge from power supply to EPT10 Wire run from power supply to Elec. Hinge, Elec. Pivot Wire run from power supply to door loop Power supply model
EL or CX

0-100', 14 gauge

0-200' max, 12 gauge

0-75', 14 gauge

0-150' max 12 gauge

0-100', 14 gauge

0-200' max, 12 gauge

PS873 or PS914

 

If you have a 2015 or later motor-drive Chexit, please refer to the instruction sheets by clicking HERE.

 


DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.