If power is cycled to the GF3000, does the automatic time delay default to factory?

Adjustable Time Delay (ATD):  Power cycling will not revert the delay to the default value.
The ATD must be set back to the default.

Adjustable Time Delay (ATD)The ATD provides a time delay to relock that is adjustable from 2 to 30 seconds.
The unit has been preset at the factory for a 3 second relock delay.
  • With door open, apply power
  • Remove 5/64” hex head screw to allow access to recessed momentary pushbutton switch.
  • Using the hex wrench provided, depress and release the recessed switch one time for each second of delay required (max. =30 seconds/min.=2 seconds). 
  • Example: To set ATD to 5 seconds, depress the recessed switch 5 times.
  • NOTE: If a mistake is made, wait 10 seconds, then repeat Step #4. 5) Reinstall hex head screw, after setting desired relock time delay.6) Close door and verify delay. 