How to test the RX switch in a Chexit device.

Chexit devices shipped after 8-24-2015 with motor driven:
 
If the RX is plugged in properly and the wires are not damaged it can be tested by pushing in the push pad.

When the push pad is pressed, the REX red LED should light up.

If it never lights up, and the physical wires and connectors are undamaged, then the switch may be at fault and would need to be replaced by a qualified installer.  

 
 


Chexit devices shipped prior to 8-24-2015 with solenoid driven:
If Chexit device goes into alarm with fast flashing red LED after the rearm time, the RX switch may be out of adjustment or defective. By pass the RX switch by shorting the two orange wires together near the plug connector. If device arms properly contact your sales office to locate an authorized representative to replace or adjust the Chexit RX switch assembly.


DISCLAIMER:

INFORMATION PROVIDED THROUGH THIS SITE IS PROVIDED TO YOU AS IS WITHOUT ANY EXPRESS REPRESENTATIONS OR WARRANTIES OF ANY KIND, AND WE MAKE NO REPRESENTATION OR WARRANTY THAT THIS SITE(OR ANY INFORMATION PROVIDED IN RESPONSE TO YOUR INQUIRY), WILL BE ACCURATE, COMPLETE, OR ERROR-FREE.

YOU AGREE THAT YOU MUST EVALUATE ALL INFORMATION AND RESPONSES, AND THAT YOU BEAR ALL RISKS ASSOCIATED WITH, THE USE OF THIS SITE, INCLUDING ANY RELIANCE ON THE ACCURACY,COMPLETENESS, OR USEFULNESS OF ANY INFORMATION OR MATERIALS MADE AVAILABLE THROUGH THIS SITE.

Other users ask